Classification
Contact Us
Address:Hongdu Industrial Zone, Linglong Street, Lin'an City, Hangzhou, Zhejiang Province, China
Contact Phone:0086-571-63832191
E-mail:sales@cx-cable.com
Mobile:0086-15968191826
Website:www.hzcxcable.com
1x4 micro PLC splitter mini splitter micro splitter plc optical splitter steel tube splitter ratio splitter 900um mini plc splitter with SC APC connector 1X4 passive PLC Splitter
Classification:
Product Details
1x4 micro PLC splitter mini splitter micro splitter plc optical splitter steel tube splitter ratio splitter 900um mini plc splitter with SC APC connector 1X4 passive PLC Splitter
Optical Characteristics
| Category | Specification | Remarks | |||
| Test Wavelength | nm | 1310&1490&1550 | |||
|
Insertion Loss
( exclude connector loss) |
U Grade | MAX | dB | 7.1 | |
| P Grade | 7.2 | ||||
| S Grade | 7.4 | ||||
|
Insertion Loss
(With connector loss) |
U Grade | MAX | dB | 7.4 | |
| P Grade | 7.5 | ||||
| S Grade | 7.7 | ||||
| Channel Uniformity | MAX | dB | 0.6 | ||
| Polarization Dependent Loss-PDL | MAX | dB | 0.2 | ||
| Directivity | MIN | dB | 55 | ||
| Return Loss | MIN | dB | 55 | ||
| Adapter Insertion Loss | MAX | dB | N/A | ||
| Working Wavelength | NM | 1260~1650 | |||
| Storage Temperature | ℃ | -40~+85 | |||
| Operating Temperature | ℃ | -40~+85 | |||
Optical cable and other requirements
| Category | Specification | Remarks | ||
| Fiber Cable | Fiber Type | G657A or G652 | ||
| Outer diameter | 900um | |||
| Tube Material | Hytrel or Requirements | |||
| Tube Colour | Translucent or Chromatic | |||
| Input endface Length:L1 | L1±5mm | L1≥0.3M | ||
| Output endface Length:L2 | L2±5mm | L2≥0.3M | ||
| Connector type | Input endface | SC、FC、LC | ||
| Output endface | SC、FC、LC | |||
| Number tube NO: | IN/Input No./Output | |||
Insertion Loss
Test Wavelength: 1310-1550 nm
Required Value:P Grade
Test can be performed on any channel
Return Loss
Test Wavelength: 1310-1550 nm
Required Value:>55dB
Test can be performed on any channel
Directivity
Test wavelength: 1310-1550 nm
Required Value:>55 dB
On Dependent Loss-PDL
Test Wavelength: 1310-1550 nm
Required Value:< 0.2 dB
Blister Box Packing
| Size(CM) | 20.7x9.2x1.2 | ||
| QTY(PCS/Box) | 1 | ||
| N.W(KG/Box) | With Connector | 0.024 | |
| Without Connector | 0.007 | ||
| G.W(KG/Box) | With Connector | 0.044 | |
| Without Connector | 0.027 | ||
Gift Box Packing(Inner packing)
| Size(CM) | 21x9.4x1.5 | ||
| QTY(Blister Box/Girt Box) | 1 | ||
| N.W(KG/Box) | With Connector | 0.024 | |
| Without Connector | 0.007 | ||
| G.W(KG/Box) | With Connector | 0.061 | |
| Without Connector | 0.044 | ||
Key words:
Cable